    問:在污水處理中,沉水風(fēng)機(jī)常見的故障有哪些?

    • 作者:超級管理員
    • 發(fā)布時(shí)間:2022-07-15
    • 點(diǎn)擊:1594

      答:由于沉水風(fēng)機(jī)在水下的特殊性,很多多年的合作客戶經(jīng)常咨詢沉水風(fēng)機(jī)的維修、保養(yǎng)、故障問題。今天,我們便將沉水風(fēng)機(jī)的常見故障與解決方法整理總結(jié),分享給大家!

      沉水風(fēng)機(jī)在運(yùn)行過程會(huì)出現(xiàn)通電無法啟動(dòng)、運(yùn)轉(zhuǎn)中突然停轉(zhuǎn)、不出水、電流過大、振動(dòng)明顯、有噪音等現(xiàn)象,將從這些問題進(jìn)行分析并找出解決的方法。若本文有可能幫助到您,請您收藏一下。以后再遇到沉水鼓風(fēng)機(jī)出現(xiàn)這些癥狀,直接從收藏夾里翻出這篇文章,一對一診斷。

      通電沉水風(fēng)機(jī)無法啟動(dòng)

      1. 故障原因

      (1)電源異常。

      (2)電源電壓太低。

      (3)電源電纜斷裂,插頭損壞。

      (4)電源缺相。

      (5)電機(jī)繞組燒損。

      (6)雜物堵塞、卡死葉輪。

      2. 解決方法

      (1)待電源正常后,重新啟動(dòng)。

      (2)正常時(shí),電源電壓三相相間電壓為 350-400V,單相電壓為 200-240V之間。否則,應(yīng)設(shè)法恢復(fù)后,再啟動(dòng)使用。

      (3)更換損壞的電纜或插頭。

      (4)查出缺相部位,更換損壞開關(guān)、熔斷器、電機(jī)引出線。

      (5)重新繞制燒損繞組。

      (6)清除雜物,但須注意不要破壞葉輪的平衡。葉輪中心螺絲有些是反絲的,拆卸時(shí)要注意。

    沉水風(fēng)機(jī)

      沉水風(fēng)機(jī)運(yùn)轉(zhuǎn)中突然停轉(zhuǎn)

      1. 故障原因

      (1)保護(hù)動(dòng)作,空氣開關(guān)跳閘或熔斷器熔斷。

      (2)電機(jī)繞組燒損。

      (3)葉輪被雜物卡死。

      2. 解決方法

      (1)查明保護(hù)動(dòng)作原因,消除故障后更換熔斷器。

      (2)重新繞制繞組。

      (3)清除雜物,注意不要破壞葉輪平衡。

      沉水風(fēng)機(jī)不曝氣

      1.故障原因

      (1)電機(jī)無法啟動(dòng)。

      (2)濾水網(wǎng)被雜物堵塞。

      (3)出水管道松脫、堵塞、破裂。

      (4)吸水口露出水面。

      (5)機(jī)體密封損壞。

      (6)風(fēng)機(jī)轉(zhuǎn)動(dòng)方向反向。

      (7)轉(zhuǎn)子和軸松脫打滑。

      2.解決方法

      (1)按無法啟動(dòng)檢查處理。

      (2)清除濾水網(wǎng)上雜物。

      (3)檢查出水管道,對癥處理。

      (4)調(diào)整沉水風(fēng)機(jī)位置。

      (5)更換損壞的密封部件。

      (6)調(diào)整電源任意兩相接線,改變相序;單相電機(jī)改變接線。

      (7)排除松脫、打滑。

      沉水風(fēng)機(jī)運(yùn)轉(zhuǎn)中電流過大

      1.故障原因

      (1)電機(jī)超載。

      (2)軸承、軸套等的密封件損壞。

      (3)軸彎曲。

      2.解決方法

      (1)調(diào)整抽水揚(yáng)程。

      (2)更換同規(guī)格密封件。

      (3)重新校正軸或更換。

      振動(dòng)增大,超出允許范圍內(nèi)

      1.故障原因

      (1)風(fēng)機(jī)中緊固件松動(dòng)。

      (2)電機(jī)轉(zhuǎn)子或葉輪平衡被破壞。

      (3)轉(zhuǎn)動(dòng)部分有雜物。

      2.解決方法

      (1)檢查并緊固所有緊固部件。

      (2)重新校正水泵平衡。

      (3)清除雜物。

      沉水風(fēng)機(jī)通電后“嗡嗡”響,卻不正常工作

      1.故障原因

      電容器損壞。

      2.解決方法

      更換損壞電容器,更換時(shí)注意不要讓泵內(nèi)的冷卻油滿出,并要擰緊相關(guān)螺絲。

      如遇上述問題,可參照本文中提到的解決方法檢查沉水風(fēng)機(jī),若沉水風(fēng)機(jī)問題嚴(yán)重的話,可咨詢生產(chǎn)廠家進(jìn)行維修。

          由于沉水風(fēng)機(jī)安裝在水下,后期的維護(hù)保養(yǎng)較為繁瑣,為幫助各位客戶解決沉水風(fēng)機(jī)的維護(hù)保養(yǎng)難題。瑞柘環(huán)保推出了上門維護(hù)保養(yǎng)服務(wù)!若您所使用的沉水式鼓風(fēng)機(jī),出現(xiàn)了無法正常運(yùn)轉(zhuǎn)的問題,可以聯(lián)系我們進(jìn)行維護(hù)保養(yǎng)或維修!

      A: Due to the particularity of submerged fan under water, many years of cooperative customers often consult the problems of maintenance, maintenance and failure of submerged fan. Today, we will sort out and summarize the common faults and solutions of submerged fan and share them with you!

      During operation of submerged fan, phenomena such as power failure, sudden stop in operation, no water supply, excessive current, obvious vibration and noise will occur. The problems will be analyzed and solutions will be found. If this article is likely to help you, please collect it. I will encounter these symptoms again later on with the submerged blower and turn this article directly out of my favorite folder for one-on-one diagnosis.

      Power-on submerged fan can not start

      1. Cause of failure

      (1) Abnormal power supply.

      (2) The supply voltage is too low.

      (3) The power cable is broken and the plug is damaged.

      (4) The power supply is out of phase.

      (5) Loss of motor winding.

      (6) Impeller is blocked and stuck by debris.

      2. Solution

      (1) Restart after the power supply is normal.

      (2) In normal condition, the three-phase voltage of power supply is 350-400V and the single-phase voltage is 200-240V. Otherwise, try to restore before starting use.

      (3) Replace damaged cables or plugs.

      (4) Find out the missing phase and replace damaged switch, fuse and motor leads.

      (5) Rewinding burnt winding.

      (6) Remove foreign matters, but care must be taken not to destroy the balance of the impeller. Some of the central screws of the impeller are reversed, which should be paid attention to when removing.

      Submerged fan

      Sudden stop of submerged fan in operation

      1. Cause of failure

      (1) Protection action, air switch tripping or fuse fusing.

      (2) Loss of motor winding.

      (3) The impeller was stuck by debris.

      2. Solution

      (1) Find out the cause of protective action and replace fuse after eliminating faults.

      (2) Rewinding.

      (3) Remove debris and take care not to destroy the balance of impeller.

      No aeration of submerged fan

      1. Cause of failure

      (1) The motor can not be started.

      (2) The water filter is blocked by debris.

      (3) The outlet pipe is loose, blocked or broken.

      (4) Water suction openings are exposed.

      (5) Seal of the body is damaged.

      (6) Fan rotates in opposite direction.

      (7) The rotor and shaft are loose and slip.

      2. Solution

      (1) Press can not start the inspection process.

      (2) Remove debris from the water filter screen.

      (3) Check water outlet pipeline and treat it symptomatically.

      (4) Adjust the position of submerged fan.

      (5) Replace damaged sealing parts.

      (6) Adjust any two-phase wiring of the power supply and change the phase sequence; Single-phase motor changes wiring.

      (7) Eliminate loosening and slipping.

      Excessive current in operation of submerged fan

      1. Cause of failure

      (1) Motor overload.

      (2) Damage to seals of bearings, bushings, etc.

      (3) Shaft bending.

      2. Solution

      (1) Adjust the pump head.

      (2) Replace seals of the same specification.

      (3) Re-correct shaft or replace it.

      Increased vibration beyond allowable range

      1. Cause of failure

      (1) The fasteners in the fan are loose.

      (2) The balance of motor rotor or impeller is destroyed.

      (3) There are foreign matters in the rotating part.

      2. Solution

      (1) Check and tighten all fastening parts.

      (2) Re-correct pump balance.

      (3) Remove foreign matters.

      "Buzzing" of submerged fan after energizing, but it does not work properly

      1. Cause of failure

      Capacitor damaged.

      2. Solution

      Replace the damaged capacitor, take care not to let the cooling oil in the pump overflow when replacing, and tighten the relevant screws.

      In case of the above problems, check the submerged fan according to the solutions mentioned in this paper. If the problems are serious, consult the manufacturer for repair.

      Because the submerged fan is installed under water, the maintenance in later period is tedious. To help customers solve the maintenance problems of submerged fan. Rye Environmental launched on-site maintenance services! If the submerged blower you are using has trouble running properly, you can contact us for maintenance or repair!


    Copyright ? 2021上海瑞柘環(huán)保設(shè)備集團(tuán)有限公司 技術(shù)支持:昆山網(wǎng)站建設(shè) 滬ICP備14047048號 XML地圖 
    在線客服
    聯(lián)系方式

    熱線電話

    15900463963

    上班時(shí)間

    周一到周五

    公司電話

    400-155-8689

    <strong id="4uciw"></strong>
  • <kbd id="4uciw"></kbd>
    <samp id="4uciw"><tbody id="4uciw"></tbody></samp>
  • <strike id="4uciw"><menu id="4uciw"></menu></strike>
  • <strike id="4uciw"><menu id="4uciw"></menu></strike>